Skip to main content
Edwards Lifesciences Logo

ForeSight Jr sensor

ForeSight Jr sensor - Banner Image
The Critical Care product group is now part of BD (Becton, Dickinson and Company). Edwards Lifesciences is the manufacturer of the products.

The ForeSight Jr sensor is different by design – giving you actionable insights to protect even the smallest patients

actionable insight
Exclusive fifth wavelength image

Exclusive fifth wavelength

Because other systems use only two, three or four wavelengths of near infrared light (NIRS), patient differences in bilirubin and meconium concentrations can cloud the accuracy – and therefore the reliability – of oxygenation measures.

With both a unique sensor design and five wavelengths NIRS, ForeSight sensor can account for these differences - enabling reliable StO2 measures from patient to patient.

Unique sensor design

Unique sensor design

Choose from three sensor models, all with design features intended to be compatible with every biocomposition, for use across all pediatric patient sizes. Each sensor offers a headwrap sensor without adhesive.

Site-specific algorithms1 image

Site-specific algorithms1

While some systems are only validated to SjvO2, the ForeSight system algorithms are calibrated and validated for both cerebral and somatic regions:

  • Cerebral (StO2) tissue oximetry is calibrated and validated to jugular bulb venous oxygen saturation (SjvO2)
  • Somatic (StO2) tissue oximetry is calibrated and validated to central venous oxygen saturation (ScvO2)
Desaturation event insights

Desaturation event insights

In addition to StO2 measurements, ForeSight sensor trends the relative change in total tissue hemoglobin (ΔctHb). The ΔctHb parameter gives you greater insights into potential causes of StO2 imbalances so that you can better understand and respond to desaturation events.

Tissue oximetry measures you can trust and treat to

Tissue oximetry measures you can trust and treat to - Image

Every patient and their needs are different. The ForeSight Jr sensor was designed to accommodate each patient’s unique anatomy and physiology to deliver cerebral tissue oximetry and somatic values that you can depend on.

Penetrate to the appropriate depth

Ensuring the appropriate penetration depth for your pediatric patient’s size is important to achieving accurate, actionable oximetry readings.

The ForeSight system offers a variety of sensor sizes and two modes of penetration – 1.25 cm and 2 cm – so that you can ensure you’re measuring the appropriate penetration depth for your patient’s anatomy.

ForeSight Jr medium sensor

ForeSight Jr 

medium sensor

Cerebral – Patients ≥ 3kg
Non-cerebral – Patients ≥ 3kg

Foresight Jr

ForeSight Jr 

small sensor

Cerebral – Patients <8kg
Non-cerebral – Patients <5kg

ForeSight Jr small non-adhesive sensor

ForeSight Jr 

small non-adhesive sensor

Cerebral – Patients <8kg
Non-cerebral – Patients <5kg

Use on the most delicate skin

Use on the most delicate skin - Image

With cushioned patient interfaces and CoolLight LED technology designed to reduce heat generation, the ForeSight Jr sensor is designed to be gentle on skin.

The ForeSight Jr sensor also maintains accuracy when used with a Tegaderm™ skin barrier.

Edwards clinical education

Comprehensive education empowering clinical advancement

With a long-term commitment to improving the quality of care for surgical and critical care patients through education, Edwards clinical education meets you no matter where you are in the learning process – with a continuum of resources and tools that continuously support you as you solve the clinical challenges facing you today, and in the future.

Product Setup

ForeSight tissue oximetry setup guide - PDF - Image

This printable guide delivers detailed instructions on how to set up the ForeSight Jr sensor with the HemoSphere advanced monitoring platform

ForeSight Jr tissue oximetry setup guide

Model numbers

ModelDescription
FSESMForeSight medium sensor (≥3 kg), 20 sensors/box
FSESSForeSight small sensor (< 8 kg), 20 sensors/box
FSESNSForeSight non-adhesive small sensor (< 8 kg), 10 sensors/box

References

  1. Benni, Paul. Validation of the Edwards FORE-SIGHT Absolute Tissue Oximeter Module for Cerebral and Somatic Tissue Oxygen Saturation (StO2%) in Adults, Transitional Adolescents in Pediatric Subjects. 2018;1-32.
Important safety information

Important safety information

CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician.
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.