Open design in the anterior portion of the mitral valve and the septal portion of the tricuspid valve
Mitral valve repair
Cosgrove-Edwards annuloplasty system
For preserving natural flexibility, when you want a flexible, open/partial band.
Models
Model | Description | Sizes | Image |
4600 | Cosgrove-Edwards annuloplasty-ring | 26, 28, 30, 32, 34, 36, 38 mm |
Accessories
Model | Description | Sizes |
1174 | Sizers - Individual | 26, 28, 30, 32, 34, 36, 38 mm |
TRAY1174 | Accessory Tray | N/A |
1150 | Reusable Bendable Handle | N/A |
1151 | Reusable Extended Handle | N/A |
Physio Flex annuloplasty ring
For remodeling while preserving flexibility, when you want a semi-rigid ring, with an open anterior segment.
Shape
Progressive anterior and posterior saddles mimic the native saddle shapes as mitral annular dimensions change
Open anterior segment corresponding to the aorto-mitral curtain design to respect the native anterior saddle-shape
Models
Model | Description | Sizes | Image |
5300 | Physio Flex annuloplasty ring | 24, 26, 28, 30, 32, 34, 36, 38, 40 mm |
Accessories
Model | Description | Sizes |
1252 | Sizers - Individual | 24, 26, 28, 30, 32, 34, 36, 38, 40 mm |
TRAY1252 | Accessory Tray | N/A |
1150 | Reusable Bendable Handle | N/A |
1151 | Reusable Extended Handle | N/A |
Carpentier-Edwards Physio II annuloplasty ring
For remodeling while preserving flexibility, when you want a semi-rigid, complete ring.
Shape
Anterior saddle and smaller posterior saddle for apposition to the aortic root
Evolves from D-Shape to more circular to accommodate the patient with larger leaflet tissue and dilated annulus
Models
Model | Description | Sizes | Image |
5200 | Carpentier-Edwards Physio II annuloplasty ring | 24, 26, 28, 30, 32, 34, 36, 38, 40 mm |
Accessories
Model | Description | Sizes |
1252 | Sizers - Individual | 24, 26, 28, 30, 32, 34, 36, 38, 40 mm |
TRAY1252 | Accessory Tray | N/A |
1150 | Reusable Bendable Handle | N/A |
1151 | Reusable Extended Handle | N/A |
Carpentier-Edwards Physio annuloplasty ring
For remodeling while preserving flexibility, when you want a semi-rigid, complete ring.
Shape
Anterior saddle shape for apposition of the aortic root
Restores anatomical size and shape to provide optimal orifice area
Models
Model | Description | Sizes | Image |
4450 | Carpentier-Edwards Physio annuloplasty ring | 24, 26, 28, 30, 32, 34, 36, 38, 40mm |
Accessories
Model | Description | Sizes |
1174 | Sizers - Individual | 24, 26, 28, 30, 32, 34, 36, 38, 40 mm |
TRAY1174 | Sizers - Accessory Tray | N/A |
1150 | Reusable Bendable Handle | N/A |
1126 | Single-Use Sizer Handle | N/A |
Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring
For rigid remodeling, when you want a rigid, complete ring with an asymmetrical design.
Shape
Asymmetrical design to compensate in tethered P2/P3 region
Dipped P3 segment to accommodate downward displacement of posterior annulus
Models
Model | Description | Sizes | Image |
4100 | Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring | 24, 26, 28, 30, 32, 34 mm |
Accessories
Model | Description | Sizes |
1174 | Sizers - Individual | 24, 26, 28, 30, 32, 34 mm |
TRAY1174 | Accessory Tray | N/A |
1150 | Reusable Bendable Handle | N/A |