Valvole pericardiche per interventi aortici Edwards Lifesciences Valvola cardiaca per interventi aortici

La gamma di valvole aortiche pericardiche Carpentier-Edwards è basata sul design della bioprotesi PERIMOUNT.

MODELLO 3300TFX
CARPENTIER-EDWARDS

MAGNA EASE

Bioprotesi aortica pericardica
MODELLO 3300TFX
CARATTERISTICHE

Profilo ribassato
Facilità di impianto
Design sovra-anulare
Possibilità di impianto di una valvola di dimensioni maggiori
Design bioingegneristico
Stent flessibile in lega CoCr
Lembi pericardici
Processo ThermaFix
MODELLI 3000/3000TFX
CARPENTIER-EDWARDS

MAGNA

Bioprotesi aortica pericardica
MODELLO 3000
CARATTERISTICHE

Design sovra-anulare
Possibilità di impianto di una valvola di dimensioni maggiori
Design bioingegneristico
Stent flessibile in lega CoCr
Lembi pericardici
Processo ThermaFix
MODELLI 2700/2700TFX
CARPENTIER-EDWARDS

PERIMOUNT

Bioprotesi aortica pericardica
MODELLO 2900
CARATTERISTICHE

Design bioingegneristico
Stent flessibile in lega CoCr
Lembi pericardici
Processo ThermaFix



Non sono disponibili dati clinici per valutare l'impatto a lungo termine dei trattamenti del tessuto di Edwards Lifesciences sui pazienti.

Valvola MAGNA Ease

Valvola cardiaca aortica Carpentier-Edwards PERIMOUNT Magna Ease

Comprovato design PERIMOUNT

  • La valvola Magna Ease è stata sviluppata a partire dal comprovato design della valvola PERIMOUNT, collaudato nel tempo, in grado di
    offrire elementi di design unici, tra cui:

Facilità di impianto

  • Offre numerose caratteristiche chiave nella progettazione che migliorano la facilità di impianto della valvola

Prestazioni emodinamiche stabili ed eccellenti

  • Valori EOA (area effettiva dell'orifizio) eccellenti e gradienti bassi documentati in studi pubblicati1-3
  • Stabilità emodinamica documentata fino a 17 anni dopo l'impianto

Eccezionale durata a lungo termine

  • Costruita sulle prestazioni riconosciute del design della valvola PERIMOUNT, con una durata clinica pubblicata fino a 20 anni
Comprovato design PERIMOUNT
Facilità di impianto
Prestazioni emodinamiche stabili ed eccellenti
Eccezionale durata a lungo termine
Comprovato design PERIMOUNT

Facilità di impianto

  • Offre numerose caratteristiche chiave nella progettazione che migliorano la facilità di impianto della valvola
Facilità di impianto

Prestazioni emodinamiche stabili ed eccellenti

  • Valori EOA (area effettiva dell'orifizio) eccellenti e gradienti bassi documentati in studi pubblicati1-3
  • Stabilità emodinamica documentata fino a 17 anni dopo l'impianto
Prestazioni emodinamiche stabili ed eccellenti

Eccezionale durata a lungo termine

  • Costruita sulle prestazioni riconosciute del design della valvola PERIMOUNT, con una durata clinica pubblicata fino a 20 anni
Eccezionale durata a lungo termine

Valvola aortica Magna Ease

Indicazioni

La bioprotesi aortica pericardica Carpentier-Edwards PERIMOUNT Magna Ease è indicata per pazienti la cui malattia valvolare aortica è sufficientemente avanzata da giustificare la sostituzione della valvola naturale con una protesica. È inoltre indicata per pazienti a cui sia stata precedentemente impiantata una protesi valvolare aortica non adeguatamente funzionante, che debba quindi essere sostituita. In quest'ultimo caso, la protesi precedentemente impiantata viene escissa chirurgicamente e sostituita con un'altra protesi.

Elenco dei materiali

  • Lembi della valvola: pericardio bovino
  • Stent: lega di cobalto-cromo
  • Tessuto a copertura dello stent: tessuto in poliestere
  • Anello di sutura della valvola: gomma siliconica

Trattamento del tessuto

  • Il modello 3300TFX è sottoposto processo ThermaFix Carpentier-Edwards per ostacolare il legame del calcio nei due principali siti: residui di glutaraldeide e fosfolipidi

Informazioni generali sul prodotto

  • Temperatura di stoccaggio: da 10 °C a 25 °C (50-77 °F)
  • Soluzione di stoccaggio: glutaraldeide
  • Procedura di risciacquo: 500 ml (soluzione fisiologica sterile) x 60 secondi. Ripetere una volta con soluzione salina nuova

ModelloDescrizioneMisureImmagine
3300TFX Bioprotesi aortica pericardica Carpentier-Edwards
PERIMOUNT Magna Ease
con processo ThermaFix
19, 21, 23, 25, 27 e 29 mm Bioprotesi aortica pericardica Carpentier-Edwards PERIMOUNT Magna Ease con processo ThermaFix‡

ModelloDescrizioneCompatibile con i modelli di valvolaMisure
1133SET Misuratori - Set completo 3300TFX 19, 21, 23, 25, 27 e 29 mm
1133 Misuratori - Singoli 3300TFX 19, 21, 23, 25, 27 e 29 mm
 TRAY1133  Vassoio per accessori 3300TFX N/D
 1111  Impugnatura riutilizzabile 3300TFX, 3000TFX, 3000 N/D
 1126  Impugnatura monouso più lunga 3300TFX, 3000TFX, 3000 N/D

Sintesi clinica:

Risultati clinici nel lunghissimo periodo della valvola Carpentier-Edwards PERIMOUNT in posizione aortica 

Scarica ora
(230 KB)



‡ Non sono disponibili dati clinici per valutare l'impatto a lungo termine dei trattamenti del tessuto di Edwards Lifesciences sui pazienti.
* Libertà da sostituzione / reintegrazione esplante / protesi a causa di SVD.
Libertà da reintervento della valvola per la disfunzione della protesi e per tutte le altre cause.

Riferimenti:
  1. Dalmau M, et al. The Carpentier-Edwards Perimount Magna aortic xenograft: a new design with an improved hemodynamic performance. Interactive Cardiovasc and Thoracic Surgery 2006;5:263–267.
  2. Ruzicka D, et al. The Complete Supraannular Concept, In Vivo Hemodynamics of Bovine and Porcine Aortic Bioprostheses. Circulation 2009;120(11 Suppl):S139-45.
  3. Wendt D, et al. The new St Jude Trifecta versus Carpentier-Edwards Magna and Magna Ease aortic bioprosthesis: Is there a hemodynamic superiority? J Thorac Cardiovasc Surg. 2014;147(5):1553-1560.
  4. Banbury MK et al. Hemodynamic Stability During 17 Years of the Carpentier-Edwards Aortic Pericardial Bioprosthesis. Ann Thorac Surg 2002;73:1460-65. (Cohort size = 267, mean age = 65 yrs.)
  5. Pelletier LC, Carrier M, Leclerc Y, et al. The Carpentier-Edwards Pericardial Bioprosthesis: Clinical Experience with 600 Patients. Ann Thorac Surg. 1995;60:S297-302. (Cohort size = 416, mean age = 63 yrs. Number at risk for Primary Valve Dysfunction at last follow-up = 18)
  6. Cosgrove DM, Lytle BW, Taylor PC, et al. The Carpentier-Edwards Pericardial Aortic Valve. Ten-year results. J Thorac Cardiovasc Surg. 1995;110(3):651 662. (Cohort size = 310; mean age = 64.2 ± 10. 8 yrs. Number at risk for Structural Valve Deterioration at last follow-up = 63)
  7. Carrier M, Pellerin M, Perrault LP, et al. Aortic Valve Replacement with Mechanical and Biologic Prosthesis in Middle-aged Patients. Ann Thorac Surg. 2001;71:S253-256. (Cohort size = 158, mean age = 61 ± 3 yrs. Number at risk for Valve Dysfunction at last follow-up not reported)
  8. Murakami T, et al. Aortic and Mitral Valve Replacement with the Carpentier-Edwards Pericardial Bioprosthesis: 10-year Results. J Heart Valve Dis. 1996 Jan;5(1):45-9. (Cohort size = 49, mean age = 58.6 ± 15.1 yrs. Number at risk for SVD at last follow-up = 1)
  9. Aupart MR, Babuty DG, Guesnier L, et al. Double Valve Replacement with the Carpentier-Edwards Pericardial Valve: 10-year Results. J Heart Valve Dis. 1996;5(3):312-316. (Cohort size = 71, mean age = 63.4 yrs. Number at risk for Valve Structural Failure at last follow-up not reported)
  10. Aupart MR, Sirinelli AL, Diemont FF, et al. The Last Generation of Pericardial Valves in the Aortic Position: Ten-year Follow-up in 589 Patients. Ann Thorac Surg. 1996;61(2):615-620. (Cohort size = 589, mean age = 67.5 ± 11.2 yrs. Number at risk for Structural Valve Failure at last follow-up not reported)
  11. Aupart M, Simonnot I, Sirinelli A, et al. Pericardial Valves in Small Aortic Annuli: Ten Years’ Results. Eur J Cardiothorac Surg. 1996;10(10):879-883. (Cohort size = 90, mean age = 72.2 ± 10.1 yrs. Number at risk for Valve Failure at last follow-up not reported)
  12. Gao G, Wu Y, Grunkemeier GL, et al. Durability of Pericardial Versus Porcine Aortic Valves. J Am Coll Cardiol. 2004;44(2):384-388. (Cohort size = 1,021, mean age = 74 yrs. Number at risk for Explant for SVD at last follow-up = 6)
  13. Le Tourneau T, Vincentelli A, Fayad G, et al. Ten-year Echocardiographic and Clinical Follow-up of Aortic Carpentier-Edwards Pericardial and Supraannular Prosthesis: a Case-match Study. Ann Thorac Surg. 2002;74(6):2010-2015. (Cohort size = 75, mean age = 72 ± 9 yrs. Number at risk for SVD or reoperation at last follow-up = 18)
  14. Banbury MK, Cosgrove DM III, Lytle BW, Smedira NG, Sabik JF, Saunders CR. Long-term Results of the Carpentier-Edwards Pericardial Aortic valve: A 12-year Follow-up.Ann Thorac Surg 1998;66:S73–6. (Cohort size = 310, mean age = 64.2 ± 10.8 yrs. Number at risk for Structural Deterioration at last followup = 111)
  15. Dellgren G, David TE, Raanani E, Armstrong S, Ivanov J, Rakowski H. Late Hemodynamic and Clinical Outcomes of Aortic Valve Replacement with the Carpentier-Edwards Perimount Pericardial Bioprosthesis. J Thorac Cardiovasc Surg 2002;124:146-54. (Cohort size = 254, mean age = 71 yrs. Number at risk for Structural Valve Dysfunction at last follow-up = 6)
  16. Nakajima H, Aupart MR, Neville PH, Sirinelli AL, Meurisse YA, Marchand MA. Twelve-year Experience with the 19 mm Carpentier-Edwards Pericardial Aortic Valve. J Heart Valve Dis 1998;7:534-539. (Cohort size = 121, mean age = 73.2 ± 9.4 yrs. Number at risk for Structural Valve Deterioration at last follow-up = 4)
  17. Neville PH, et al. Carpentier-Edwards Pericardial Bioprosthesis in Aortic or Mitral Position: a 12-year Experience. Ann Thorac Surg. 1998;66(6 Suppl):S143-7. (Cohort size = 787, mean age = 68.83± 10.8` yrs. Number at risk for Structural Deterioration at last follow-up = 13)
  18. Pellerin M, Mihaileanu S, Couetil JP, Relland JYM, Deloche A, Fabiani JN, Jindani A, Carpentier AF. Carpentier-Edwards Pericardial Bioprosthesis in Aortic Position: Long-term Follow-up 1980 to 1994. Ann Thorac Surg. 1995;60:S292-6. (Cohort size = 124, mean age = 65 yrs. Number at risk for Structural Valve Deterioration at last follow-up = 8)
  19. Frater RWM, Furlong P, Cosgrove DM, Okies JE, Colburn LQ, Katz AS, Lowe NL, Ryba EA. Long-term Durability and Patient Functional Status of the Carpentier-Edwards Perimount Pericardial Bioprosthesis in the Aortic Position. J Heart Valve Dis. 1998;7:48-53. (Cohort size = 267, mean age = 64.9 ± 11.8 yrs. Number at risk for Valve Dysfunction at last follow-up = 28)
  20. Poirier NC, et al. 15-year Experience with the Carpentier-Edwards Pericardial Bioprosthesis. Ann Thorac Surg. 1998;66:S57-61. (Cohort size = 598, mean age = 65 yrs. Number at risk for Structural Deterioration at last follow-up = 8)
  21. Banbury MK, Cosgrove DM III, White JA, et al. Age and Valve Size Effect on the Long-term Durability of the Carpentier-Edwards Aortic Pericardial Bioprosthesis. Ann Thorac Surg. 2001;72(3):753-757. (Cohort size = 267, mean age = 65 ± 12 yrs. Number at risk for Explant for SVD at last follow-up not reported)
  22. McClure RS, Narayanasamy N, Wiegerinck E, et al. Late Outcomes for Aortic Valve Replacement with the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-year Follow-up in 1,000 Patients. Ann Thorac Surg. 2010;89(5):1410-1416. (Cohort size = 1,000, mean age = 74.1 ± 0.29 yrs. Number at risk for SVD at last follow-up not reported)
  23. Minakata K et al. Long-Term Outcome of the Carpentier-Edwards Pericardial Valve in the Aortic Position in Japanese Patients. Circulation Journal 2014;78:882-889. (Cohort size = 574, mean age = 71.9 yrs. Number at risk for Structural Deterioration at 15-year follow-up = 54)
  24. Jamieson WR, Germann E, Aupart MR, et al. 15-year Comparison of Supra-annular Porcine and PERIMOUNT Aortic Bioprostheses. Asian Cardiovasc Thorac Ann. 2006;14(3):200-205. (Cohort size = 1,430, mean age = 69.5 ± 10.4 yrs. Number at risk for SVD at last follow-up = 33)
  25. Biglioli P, Spampinato N, Cannata A, et al. Long-term outcomes of the Carpentier-Edwards pericardial valve prosthesis in the aortic position: effect of patient age. J Heart Valve Dis. 2004;13(1):S49-51. (Cohort size = 327, mean age = 67.2 ± 10.6 yrs. Number at risk for Prosthesis Replacement at last follow-up not reported)
  26. Bergoënd E, Aupart MR, Mirza A, et al. 20 years’ durability of Carpentier-Edwards Perimount stented pericardial aortic valve. In: Yankah CA, Weng Y, Hetzer R, eds. Aortic Root Surgery The Biological Solution. Berlin: Springer; 2010:441-451. (Cohort size = 1,857, mean age = 69.8 yrs, Number at risk for Structural Valve Deterioration at last follow-up not reported)
  27. Aupart MR, Mirza A, Meurisse YA, et al. Perimount Pericardial Bioprosthesis for Aortic Calcified Stenosis: 18-year Experience with 1133 Patients. J Heart Valve Dis. 2006;15(6):768-775. (Cohort size = 1,133, mean age = 72.6 yrs. Number at risk for SVD at last follow-up = 2)
  28. Forcillo J et al. Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience. Ann Thorac Surg 2013;96:486-93. (Cohort size = 2,405, mean age = 71 yrs. Number at risk for Structural Deterioration at last follow-up = 30)
  29. Carpentier-Edwards PERIMOUNT Aortic Pericardial Bioprosthesis 20-year Results. Data on file at Edwards Lifesciences, 2003. (Cohort size = 267, mean age = 65 ± 12 yrs. For patients ≥65, number at risk for explant due to SVD at last follow-up = 2)
VALVOLA MAGNA

Valvola cardiaca aortica Carpentier-Edwards PERIMOUNT Magna

La valvola Magna (bioprotesi) presenta un reale design sovra-anulare per caratteristiche emodinamiche e di flusso ottimali.

  • Consente di ottenere un aumento dell'area effettiva dell'orifizio (EOA) fino al 23%**
  • Offre prestazioni emodinamiche eccezionali con un rischio molto basso di mismatch protesi-paziente30
  • Progettata a partire dalla valvola aortica PERIMOUNT, con una durata clinica pubblicata fino a 20 anni

Valvola aortica Magna

Valvola aortica Magna

Design

  • Il design bioingegneristico basato su modelli matematici è studiato per ottimizzare emodinamica, durata e impiantabilità
  • lo stent flessibile in lega di cobalto-cromo
  • Tre lembi pericardici bovini indipendenti con uguale spessore ed elasticità ottimizzano la distribuzione dello stress

Indicazioni

La bioprotesi aortica pericardica Carpentier-Edwards PERIMOUNT Magna è indicata per pazienti la cui malattia valvolare aortica è sufficientemente avanzata da giustificare la sostituzione della valvola naturale con una protesica. È inoltre indicata per pazienti a cui sia stata precedentemente impiantata una protesi valvolare aortica non adeguatamente funzionante, che debba quindi essere sostituita. In quest'ultimo caso, la protesi precedentemente impiantata viene escissa chirurgicamente e sostituita con un'altra protesi.

Elenco dei materiali

  • Lembi della valvola: pericardio bovino
  • Stent: lega di cobalto-cromo
  • Tessuto a copertura dello stent: tessuto in poliestere
  • Anello di sutura della valvola: gomma siliconica

Trattamento del tessuto

  • Il modello 3000 è sottoposto al trattamento XenoLogiX, un processo in due fasi volto all'eliminazione dei fosfolipidi residui

Informazioni generali sul prodotto

  • Temperatura di stoccaggio: da 10 °C a 25 °C (50-77 °F)
  • Soluzione di stoccaggio: glutaraldeide
  • Procedura di risciacquo: 500 ml (soluzione fisiologica sterile) x 60 secondi. Ripetere una volta con soluzione salina nuova

ModelloDescrizioneMisureImmagine
3000 Bioprotesi aortica pericardica Carpentier-Edwards
PERIMOUNT Magna
19, 21, 23, 25, 27 e 29 mm 3000


Misuratori e accessori
Modello 1130SET Set di misuratori completo
Modello 1130SET
Modello 1130 Misuratori - Singoli
Modello 1130
Modello Tray1130 Vassoio per accessori
Modello 1111 Impugnatura riutilizzabile
Modello 1111
Modello 1126 Impugnatura monouso (più lunga)
Modello 1126

Sintesi clinica:

Risultati clinici nel lunghissimo periodo della valvola Carpentier-Edwards PERIMOUNT in posizione aortica 

Scarica ora
(230 KB)



‡ Non sono disponibili dati clinici per valutare l'impatto a lungo termine dei trattamenti del tessuto di Edwards Lifesciences sui pazienti.
** Rispetto a una valvola di PERIMOUNT con lo stesso diametro dell'anello di sutura esterno.

Riferimenti:
  1. Magna Ease valve Instructions for Use
VALVOLA PERIMOUNT

Valvola cardiaca aortica Carpentier-Edwards PERIMOUNT

La valvola aortica Carpentier-Edwards PERIMOUNT è la prima valvola frutto della bioingegneria meccanica progettata specificamente per la posizione aortica. Unisce un design comprovato ai vantaggi del tessuto pericardico.
  • La valvola aortica PERIMOUNT offre prestazioni eccellenti con una durata comprovata pubblicata fino a 20 anni
  • Le valvole aortiche PERIMOUNT sono supportate da 17 anni di stabilità emodinamica comprovata

Design comprovato

  • Il design di ingegneria biomedica basato su modelli matematici è studiato per ottimizzare emodinamica, durata e impiantabilità
  • Lo stent in lega di cobalto e cromo flessibile assorbe l'energia per ridurre lo stress sui lembi
  • Tre lembi pericardici bovini indipendenti con uguale spessore ed elasticità ottimizzano la distribuzione dello stress

Valvola aortica PERIMOUNT

Valvola aortica PERIMOUNT

Indicazioni

La bioprotesi aortica pericardica Carpentier-Edwards PERIMOUNT è indicata per pazienti la cui malattia valvolare aortica è sufficientemente avanzata da giustificare la sostituzione della valvola naturale con una protesica. È inoltre indicata per pazienti a cui sia stata precedentemente impiantata una protesi valvolare aortica non adeguatamente funzionante, che debba quindi essere sostituita. In quest'ultimo caso, la protesi precedentemente impiantata viene escissa chirurgicamente e sostituita con un'altra protesi.

Elenco dei materiali

  • Lembi della valvola: pericardio bovino
  • Stent: lega di cobalto-cromo
  • Tessuto a copertura dello stent: tessuto in poliestere
  • Anello di sutura della valvola: gomma siliconica

Trattamento del tessuto

  • Il modello 2900 è sottoposto al trattamento XenoLogiX, un processo in due fasi volto all'eliminazione dei fosfolipidi residui

Informazioni generali sul prodotto

  • Temperatura di stoccaggio: da 10 °C a 25 °C (50-77 °F)
  • Soluzione di stoccaggio: glutaraldeide
  • Procedura di risciacquo: 500 ml (soluzione fisiologica sterile) x 60 secondi. Ripetere una volta con soluzione salina nuova

  Modello  DescrizioneMisuraImmagine
2900 Bioprotesi aortica pericardica Carpentier-Edwards 
PERIMOUNT
19, 21, 23, 25, 27 e 29 mm

  Modello  DescrizioneCompatibile con i modelli di valvolaMisure
 1127-SET  Misuratori - Set completo 2900 Include tutto
 1127  Misuratori - Singoli 2900 19, 21, 23, 25, 27 e 29 mm
 TRAY1161  Vassoio per accessori 2900 N/D
 1111  Impugnatura riutilizzabile 3300TFX, 3000, 2900 N/D
 1126  Impugnatura monouso più lunga 3300TFX, 3000, 2900 N/D

Sintesi clinica:

Risultati Clinici nel lunghissimo periodo della valvola Carpentier-Edwards PERIMOUNT in posizione aortica

Scarica ora
(230 KB)



‡ Non sono disponibili dati clinici per valutare l'impatto a lungo termine dei trattamenti del tessuto di Edwards Lifesciences sui pazienti.

I vantaggi di Edwards

La nostra azienda si impegna a fornire a istituti, medici e staff clinici i più alti livelli di supporto e assistenza clienti.

per ricevere da Edwards Lifesciences informazioni esclusive in relazione a sostituzioni e riparazioni valvolari, congressi, studi clinici, soluzioni ed eventi.

Voi siete molto occupati – Noi siamo flessibili
Indicate i vostri argomenti di interesse e la frequenza con cui desiderate ricevere le nostre comunicazioni

IMPORTANTI INFORMAZIONI SULLA SICUREZZA

IMPORTANTI INFORMAZIONI SULLA SICUREZZA

Per uso professionale. Per informazioni complete sulla prescrizione, incluse indicazioni, controindicazioni, avvertenze, precauzioni ed eventi avversi, consultare le Istruzioni per l'uso.

I dispositivi Edwards Lifesciences in vendita nel mercato europeo e conformi ai requisiti essenziali di cui all'articolo 3 della direttiva 93/42/CEE concernente i dispositivi medici recano il marchio di conformità CE.